Pull-In Test
Connect 2 battery negative leads onto magnetic switch body and terminal C respectively. See Figure. Then connect battery positive lead onto terminal 50. Pinion should extend when lead connections are made.
Connect 2 battery negative leads onto magnetic switch body and terminal C respectively. See Figure. Then connect battery positive lead onto terminal 50. Pinion should extend when lead connections are made.