Check Keyless Entry Control Module
STEP CHECK SHEET
| Step | Check | Yes | No |
|---|---|---|---|
1. CHECK DIAGNOSTIC TROUBLE CODE (DTC)
|
Is DTC B0500 "Keyless UART com. Malfunction" displayed? | Go to step 2. | Keyless entry control module is normal. |
2. CHECK POWER SUPPLY.
Connector & terminal (i96) No. 4 (+) - Chassis ground (-): |
Is the voltage more than 10 V? | Go to step 3. | Check the harness for open circuits and shorts between the keyless entry control module and fuse. |
| 3. CHECK GROUND CIRCUIT. Measure the resistance between the harness connector terminal and chassis ground. Connector & terminal (i96) No. 7- Chassis ground: |
Is the resistance less than 10 Ω? | Go to step 4. | Repair the harness. |
4. CHECK KEYLESS ENTRY CONTROL MODULE CIRCUIT.
Connector & terminal (i84) No. 9 - (i96) No. 3: |