EGR Valve Control
CAUTION:
After performing the Operation Check Mode, perform the Clear Memory Mode <Ref. to
OPERATION , Clear Memory Mode .>.
- On the «System Operation Check Mode» display screen, select {EGR Valve Control}.
- On the «Start the Engine» display screen, start the engine and select the [OK].
- In the «EGR Valve Control» screen, select the [↑] or the [↓] to change the setting values, then select the [OK].
Setting is possible in increments of 1 STEP. However, the number of STEPs that can actually be controlled will vary depending on the vehicle.
- Select the [NO] to end the EGR valve control. The screen will return to the «System Operation Check Mode» screen.NOTE: For detailed operation procedure, refer to the "SUBARU SELECT MONITOR OPERATION MANUAL".