Check With SUBARU Select Monitor
CAUTION:
Check whether the wiper deicer timer is in initial setting or customize setting before performing inspection.
- Check the input signal when the wiper deicer switch is operated using Subaru Select Monitor.
- Prepare the Subaru Select Monitor kit. < Ref. to PREPARATION TOOL , General Description.>
- Turn the ignition switch to ON (engine OFF), and run the "PC application for Subaru Select Monitor".
- On the « System Selection Menu » display screen, select the {Integ. Unit mode}.
- Select the {Current Data Display & Save}.
- Display the data of the wiper deicer switch.
- When wiper deicer switch is turned to ON, check whether it turns to OFF in 15 minutes, or it operates continuously.
- If it turns to OFF in step 2) above, it is normal. When it operates continuously, replace the body integrated unit.