Select Cable: Installation

  1. Install the select cable to plate assembly.

    Tightening torque: 

    T: 18 N.m (1.8 kgf-m, 13.3 ft-lb) 

    Fig 1: Installing Select Cable To Plate Assembly
    G05019691Courtesy of SUBARU OF AMERICA, INC.
  2. Install the select cable to range select lever.
  3. Install the plate assembly to transmission.

    Tightening torque: 

    24.5 N.m (2.5 kgf-m, 18.1 ft-lb) 

    Fig 2: Installing Select Cable To Range Select Lever
    G05664324Courtesy of SUBARU OF AMERICA, INC.
  4. Install the washer and snap pin to range select lever.
    Fig 3: Installing Washer And Snap Pin To Range Select Lever
    G05664325Courtesy of SUBARU OF AMERICA, INC.
  5. Install new clamp paying attention to the installing direction.
    Fig 4: Installing Clamp In Proper Direction
    G05664326Courtesy of SUBARU OF AMERICA, INC.
  6. Insert the tip of inner cable into connector hole of select lever, and fix the cable to bracket.
    Fig 5: Inserting Tip Of Inner Cable Into Connector Hole Of Select Lever
    G05019697Courtesy of SUBARU OF AMERICA, INC.
  7. Shift the select lever to the "N" range, and then adjust the select cable position. < Ref. to ADJUSTMENT , Select Cable . >
  8. Install the heat shield cover.
  9. Install the front, center and rear exhaust pipe, and the muffler. < Ref. to INSTALLATION , Front Exhaust Pipe . > < Ref. to INSTALLATION , Rear Exhaust Pipe . > < Ref. to INSTALLATION , Muffler . >