Fuel Sub Level Sensor: Installation
Install in the reverse order of removal while being careful of the following.
- Make sure the sealing portion is free from fuel or foreign matter before installation.
- Align the protrusion (A) of gasket with the position shown in the figure.
- Align protrusion (B) of the fuel sub level sensor to the cut out in the fuel sublevel sensor upper plate.
- Tighten the nuts and bolts to the specified torque in the order as shown in the figure.
NOTE:
Use a new gasket and retainer.
Tightening torque:
4.4 N.m (0.4 kgf-m, 3.2 ft-lb)