Fuel Sub Level Sensor: Installation
Install in the reverse order of removal by adhering to the following procedures.
- Make sure the sealing portion is free from fuel or foreign matter before installation.
- Align the protrusion (A) of gasket to the position shown in the following illustration.
- Align the protrusion (B) of fuel sub level sensor with the cutout portion of fuel sub level sensor upper plate.
- Tighten the nuts and bolts to the specified torque in the order as shown in the illustration.
NOTE:
Use a new gasket and a retainer.
Tightening torque:
4.4 N.m (0.4 kgf-m, 3.2 ft-lb)