Mode $06
Refer to test value of troubleshooting and data of test limit indicated on the support data bit sequence table. A list of the support data is shown in the following table.
| OBDMID | TID | SID | Diagnostic item |
|---|---|---|---|
| $01 | $81 | $0A | A/F sensor continuity failure (Bank 1 Sensor 1) |
| $82 | $8D | ||
| $83 | $14 | ||
| $84 | $1E | A/F sensor range failure (Bank 1 Sensor 1) | |
| $85 | $1E | ||
| $86 | $20 | A/F sensor response failure (Bank 1 Sensor 1) | |
| $02 | $87 | $0B | Oxygen sensor circuit failure (Bank 1 Sensor 2) |
| $88 | $0B | ||
| $07 | $0B | Oxygen sensor drop failure (Bank 1 Sensor 2) | |
| $08 | $0B | ||
| $A5 | $0B | ||
| $05 | $10 | Oxygen sensor response failure (Bank 1 Sensor 2) | |
| $06 | $10 | ||
| $21 | $89 | $20 | Catalyst deterioration diagnosis (Bank 1) |
| $31 | $8A | $FD | EGR system diagnosis |
| $39 | $93 | $FE | Evaporative emission control system (Cap off) |
| $3B | $94 | $FE | Evaporative emission control system (0.04 inch leak) |
| $95 | $FE | ||
| $A6 | $FE | ||
| $3C | $96 | $FE | Evaporative emission control system (0.02 inch leak) |
| $97 | $FE | ||
| $3D | $98 | $FE | Evaporative emission control system (Purge flow) |
| $41 | $99 | $24 | A/F sensor heater failure (Bank 1 Sensor 1) |
| $9A | $24 | ||
| $9B | $14 | A/F sensor heater characteristics failure (Bank 1 Sensor 1) | |
| $42 | $9C | $24 | Oxygen sensor heater failure (Bank 1 Sensor 1) |
| $9D | $24 | ||
| $A1 | $0B | $24 | Misfire monitoring (All cylinders) |
| $0C | $24 | ||
| $A2 | $0B | $24 | Misfire monitoring (#1 cylinder) |
| $0C | $24 | ||
| $A3 | $0B | $24 | Misfire monitoring (#2 cylinder) |
| $0C | $24 | ||
| $A4 | $0B | $24 | Misfire monitoring (#3 cylinder) |
| $0C | $24 | ||
| $A5 | $0B | $24 | Misfire monitoring (#4 cylinder) |
| $0C | $24 |