Knock Sensor: Inspection
- Check that the knock sensor has no deformation, cracks or other damages.
- Measure the resistance between knock sensor terminals.
Courtesy of SUBARU OF AMERICA, INC.
RESISTANCE REFERENCE CHART
| Terminal No. |
Standard |
| 1 and 2 |
560±28 kΩ |