Check With SUBARU Select Monitor
CAUTION:
Before performing the inspection, check the following settings.
- Wiper deicer setting → "support". If "no support", set to "support" using customize setting.
- Rr Defogger op. mode setting → Initial setting or customize setting.
- Check the input signal when the rear window defogger switch is operated using Subaru Select Monitor.
- Prepare the Subaru Select Monitor. Refer to , PREPARATION TOOL , General Description.
- Turn the ignition switch to ON (engine OFF) and run the "PC application for Subaru Select Monitor".
- On << System Selection Menu >> display, select {Integ. unit mode}.
- Select the {wiper deicer output} on {Current Data Display & Save}.
- Check the displayed data (ON/OFF) by operating the rear window defogger switch.
- Check the operation with rear window defogger switch ON.
- When customize setting is set as "Continuous", it is normal if the 15-minute operation and 2-minute stop repeats.
- When customize setting is "Normal", it is normal if the operation lasts for 15 minutes and then turns OFF.
- When the operation in 2) above fails, replace the body integrated unit.