LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 2012 >> Outback Base, Standard Trans >> Repair and Diagnosis >> Electrical >> Charging Systems >> Starting/Charging Systems (H4SO) >> Generator >> Inspection >> Diode (3.6 L Model)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diode (3.6 L Model)

CAUTION: There is the possibility of damaging the diodes if a mega-tester (used to measure high voltages) or a similar measuring instrument is used. Never use a mega tester or equivalent for this test.
  1. Check for continuity between the diode lead and terminal E or B. If continuity is not as shown in the table, replace the rectifier.
    • At analog type tester
Tester lead Continuity
-lead +lead
E P1, P2, P3, P4, P5, P6 Yes
B None
P1, P2, P3, P4, P5, P6 E None
B Yes
Tester lead Continuity
-lead +lead
E P1, P2, P3, P4, P5, P6 None
B Yes
P1, P2, P3, P4, P5, P6 E Yes
B None
Fig 1: Checking Continuity Between Diode Lead And Terminal E Or B
G06648709Courtesy of SUBARU OF AMERICA, INC.