Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| (1) |Throttle position sensor 1 opening angle - (Throttle position sensor 1 opening angle after passing amplifier/4)| | < 3 ° |
| (2) |Standard voltage - Readings of voltage value| | < 0.078125 V |
Time Needed for Diagnosis:
- 24 ms
- 200 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.