Diagnostic Procedure
DIAGNOSTIC PROCEDURE
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK CURRENT DATA.
NOTE:
|
Is the value in «Atmosphere Pressure» 125 kPa (938 mmHg, 36.9 inHg) or more? | Go to step 2 . | Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE:
In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
|
2 CHECK HARNESS BETWEEN ECM AND LEAK CHECK VALVE ASSEMBLY CONNECTOR.
|
Is the resistance less than 1 Ω? | Go to step 3 . | Repair the harness and connector.
NOTE:
In this case, repair the following item:
|
| 3 CHECK FOR POOR CONTACT. Check for poor contact of ECM and the leak check valve assembly connector. |
Is there poor contact in ECM and the leak check valve assembly connector? | Repair the poor contact of ECM and the leak check valve assembly connector. | Go to step 4 . |
| 4 CHECK LEAK CHECK VALVE ASSEMBLY. Check the pressure sensor of the leak check valve assembly. Refer to CHECK PRESSURE SENSOR , INSPECTION, Leak Check Valve Assembly. > |
Is the pressure sensor of the leak check valve assembly OK? | Repair the short circuit to power in harness between ECM and leak check valve assembly connector. | Replace the leak check valve assembly. Refer to LEAK CHECK VALVE ASSEMBLY . > |