Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Output terminal for heater characteristics failure detection | Low |
Time Needed for Diagnosis: 4 ms x 2500 time(s)
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.