EGR Valve Control
CAUTION:
After executing the system operation check mode, execute the Clear Memory Mode. Refer to
OPERATION , Clear Memory Mode.
- On «System Operation Check Mode» display, select {EGR Valve Control}.
- On «Start the Engine» display, start the engine and click the [OK] button.
- In the «EGR Valve Control» display, click the [ ↑] button or the [ ↓] button to change the setting values, then click the [OK] button. Setting is possible in increments of 1 STEP. However, the STEP number that can actually be controlled will vary depending on the vehicle.
Setting is possible in increments of 1 STEP. However, the STEP number that can actually be controlled will vary depending on the vehicle.
- Click the [Cancel] button to stop the EGR valve control.
- Click the [F12Exit] button to end the EGR valve control. The screen will return to the «System Operation Check Mode» screen.
NOTE:
For detailed operation procedures, refer to " Subaru Select Monitor".