Unit Inspection
- Engine oil temperature sensor check
Courtesy of SUBARU OF AMERICA, INC.
- Resistance check
- Measure the resistance between the terminals.
Resistance
Inspection terminals Inspection conditions Standard value 1 - 2 Approx. 20°C {68°F} 2.25 to 2.65kΩ Approx. 80°C {176°F} 0.305 to 0.331 kΩ CAUTION: When the inspection is performed with the sensor immersed in water, be careful not to allow the ingress of water into the terminal part. After inspection is completed, wipe off the water drops from the sensor.
- Resistance check