Active Test: Operation
CAUTION:
After executing the system operation check mode, execute the Clear Memory Mode. <Ref. to
OPERATION , Clear Memory Mode.>
NOTE:
For operation procedures, refer to the "Help for Subaru Select Monitor".
- On «Start» display, select «Diagnosis».
- On «Vehicle selection» display, input the vehicle information and select «Confirmed».
- On «Main Menu» display, select «Each System».
- On «Select System» display, select «Engine Control System» and then select «Enter».
- On «Select Function» display, select «Active Test».
| Active test items | Contents | Execution condition |
|---|---|---|
| Fuel Pump Control (ON/OFF Dr.) | ON/OFF of the fuel pump can be set. | Ignition switch is ON (engine OFF) |
| CPC Solenoid Valve | ON/OFF of the purge control solenoid valve can be set. | |
| Radiator Fan Relay | ON/OFF of the radiator fan relay can be set. | |
| A/C Compressor Relay | ON/OFF of the A/C relay can be set. | |
| Turbocharger Wastegate Solenoid | Wastegate control solenoid valve can be set between 0.0% ←→ 99.6%. | |
| CPC Solenoid 2 | ON/OFF of the purge control solenoid valve 2 can be set. | |
| ELCM switching valve | ON/OFF of the leak check valve assembly switching valve can be set. | |
| ELCM pump | ON/OFF of the leak check valve assembly vacuum pump can be set. | |
| Fuel Pump Control (OFF Drive) | Fuel pump can be set to OFF. | At idling |
| Fixed Idle Ignition Timing | Idle ignition timing can be set and fixed to 10.0°. | |
| Idle Speed Control | Idle speed can be set to 500 - 2000 rpm. | |
| Injection Stop Mode (Injector 1) Injection Stop Mode (Injector 2) Injection Stop Mode (Injector 3) Injection Stop Mode (Injector 4) |
Injector of each cylinder can be set to stop the fuel injection. | |
| Injection Quantity Control | The amount of fuel injection can be set to 0 - 20%. | |
| EGR Valve Control | EGR control valve can be set to 0 - 255 STEP. | |
| High Pressure Fuel Inspection | High pressure fuel pipe inspection can be executed. | |
| Alternator control | Alternator control mode can be set to one of the followings: Low mode Middle mode High mode ExHigh mode |
|
| Compression monitor | Compression can be measured. |
|