Seat Belt Warning System: Inspection
CAUTION:
- Before handling the airbag system components, refer to "CAUTION" of "General Description" in "AIRBAG SYSTEM". <Ref. to CAUTION , General Description.>
- When inspecting the airbag main harness, disconnect the connectors of the driver's airbag module, passenger's airbag module and knee airbag module for safety reasons.
- When inspecting the airbag rear harness, disconnect the side airbag module connector, curtain airbag module connector and seat belt pretensioner connector for safety reasons.
TROUBLE SYMPTOM:
- Driver's side seat belt warning light does not illuminate or it remains illuminating.
- Warning buzzer does not beep.
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK FUNCTION.
|
Do the driver's warning light and passenger's warning light blink and the buzzer sound while blinking? | Go to step 2 . | Go to step 12 . |
2 CHECK FUNCTION.
|
Do the seat belts warning light illuminate ←→ go off according to the operation? | Go to step 3 . | Go to step 8 . |
3 CHECK FUNCTION.
|
Do the driver's warning light and passenger's warning light blink and the buzzer sound while blinking? | Go to step 4 . | Go to step 14 . |
4 CHECK HARNESS.
|
Is the harness normal? | Go to step 5 . | Repair or replace the harness. |
| 5 CHECK HARNESS. Measure the resistance between the seat belt buckle switch LH and chassis ground. Connector & terminal (R107) No. 1 - Chassis ground: |
Is the resistance less than 10 Ω? | Go to step 6 . | Repair or replace the harness. |
| 6 CHECK SEAT BELT BUCKLE SWITCH LH. Measure the resistance between the connector terminals of the driver's seat belt switch when the driver's seat belt is fastened and detached. Connector & terminal (R107) No. 2 - (R107) No. 1: |
Is the resistance when the belt is fastened 1 MΩ or more, and less than 10 Ω when the belt is detached? | Go to step 7 . | Replace the seat belt inner - front LH. <Ref. to SEAT BELT OUTER - FRONT , REMOVAL, Front Seat Belt.> |
| 7 CHECK COMBINATION METER. Perform the self-diagnosis of combination meter. <Ref. to SELF-DIAGNOSIS DISPLAY MODE , OPERATION, Combination Meter System.> |
At the start of combination meter self diagnosis, did the buzzer sound and the seat belt warning light illuminate? | Replace the combination meter. There may be a reception failure of the combination meter. | Replace the combination meter. <Ref. to REMOVAL , Combination Meter.> |
8 CHECK DATA MONITOR.
|
Does the seat belt switch display turn ON ←→ OFF according to the operation of the seat belt buckle? | Go to step 12 . | Go to step 9 . |
| 9 CHECK AIRBAG SYSTEM AND OCCUPANT DETECTION SYSTEM. Perform the check in accordance with the diagnostic procedure DTC B1650 of the airbag system. <Ref. to DTC B1650 OCCUPANT DETECTION SYSTEM MALFUNCTION , Diagnostic Procedure with Diagnostic Trouble Code (DTC).> |
Is the inspection result normal? | Go to step 10 . | Repair or replace with new parts according to DTC B1650. |
| 10 CHECK BUCKLE SWITCH RH. Perform the check in accordance with the diagnostic procedure DTC B1655 of the occupant detection system. <Ref. to DTC B1655 FRONT BUCKLE SWITCH RH FAILURE , Diagnostic Procedure with Diagnostic Trouble Code (DTC).> |
Is the inspection result normal? | Go to step 11 . | Repair or replace with new parts according to DTC B1655. |
| 11 CHECK AIRBAG CONTROL MODULE AND COMBINATION METER. Check the airbag control module, occupant detection sensor and seat belt buckle switch RH. Perform the check in accordance with the diagnostic procedure DTC B16F1 of the airbag system. <Ref. to DTC B16F1 PASSENGER'S SEAT BELT WARNING FAILURE , Diagnostic Chart with Trouble Code.> |
Is the inspection result normal? | Replace the combination meter. <Ref. to REMOVAL , Combination Meter.> | Repair or replace with new parts according to DTC B16F1. |
12 CHECK MFD POWER SUPPLY VOLTAGE.
|
Is the voltage 10 V or more? | Go to step 13 . | Check the harness for open or short between the fuse and MFD. |
13 CHECK MFD GROUND CIRCUIT.
|
Is the resistance less than 10 Ω? | Go to step 14 . | Repair or replace the harness. |
14 CHECK HARNESS BETWEEN MFD AND COMBINATION METER.
|
Is the resistance less than 10 Ω? | Go to step 15 . | Repair or replace the harness. |
15 CHECK COMMUNICATION STATUS BETWEEN MFD AND COMBINATION METER.
|
Is the MFD properly displayed? | Replace the MFD. | Replace the combination meter case assembly. |