Unit Inspection
- Inspection of IG2 relay (IG2)
- Measure the resistance between the terminals.
STANDARD VALUE RESISTANCE SPECIFICATIONInspection terminals Inspection conditions Standard value 3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ω or more 3 - 5 When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω - Inspection of EFI relay (EFI MAIN1)
- Measure the resistance between the terminals.
STANDARD VALUE RESISTANCE SPECIFICATIONInspection terminals Inspection conditions Standard value 3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ω or more 3 - 5 When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω - Inspection of EFI relay (EFI MAIN2)
- Measure the resistance between the terminals.
STANDARD VALUE RESISTANCE SPECIFICATIONInspection terminals Inspection conditions Standard value 3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ω or more 3 - 5 When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω - Inspection of EFI relay (EFI MAIN3)
- Measure the resistance between the terminals.
STANDARD VALUE RESISTANCE SPECIFICATIONInspection terminals Inspection conditions Standard value 3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ω or more 3 - 5 When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω - Inspection of INJ relay (INJ)
- Measure the resistance between the terminals.
STANDARD VALUE RESISTANCE SPECIFICATIONInspection terminals Inspection conditions Standard value 3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ω or more 3 - 5 When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω - Inspection of ETCS relay (ETCS)
- Measure the resistance between the terminals.
STANDARD VALUE RESISTANCE SPECIFICATIONInspection terminals Inspection conditions Standard value 3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ω or more 3 - 5 When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω - Inspection of F/PMP relay (C/OPEN)
- Measure the resistance between the terminals.
STANDARD VALUE RESISTANCE SPECIFICATION
| Inspection terminals | Inspection conditions | Standard value |
|---|---|---|
| 3 - 5 | When the battery voltage is not applied to the terminal 1 and terminal 2: | 10 k Ω or more |
| 3 - 5 | When the battery voltage is applied to the terminal 1 and terminal 2: | Less than 1 Ω |