Electrical Specification
| Item | Connector No. | Terminal No. | Input/Output signal |
|---|---|---|---|
| Measured value and measuring conditions | |||
| Battery power supply | B280 | 4 | 9 - 16 V |
| B281 | 32 | ||
| TCM ("P" range) | i171 | 2 | Pulse signal (CAN communication) |
| 22 | |||
| Stop light switch | B281 | 12 | 9 - 16 V when stop light switch is ON Less than 1.5 V when stop light switch is OFF |
| "P" range switch | i171 | 25 | Less than 1.5 V when select lever is in "P" range 9 - 16 V when select lever is in other positions than "P" range |
| Solenoid unit output | i84 | 3 | 8.5 - 16 V when shift lock is released Less than 1.5 V when shift lock is operating |
| Key warning switch signal (Model without push button ignition switch) |
i84 | 10 | 9 - 16 V when key is inserted Less than 1.5 V when key is removed |
| Key lock solenoid signal (Model without push button ignition switch) |
B280 | 5 | 7.5 - 16 V when the key is inserted with the select lever shifted in positions other than "P" range 0 V at other conditions than above |
| Ground | i84 | 4 | 1 V or less |
| B280 | 2 |