VDC Sensor Midpoint Setting Mode
After installing, replacing or adjusting the following parts, perform the VDC sensor midpoint setting mode.
- Steering angle sensor
- Steering wheel
- Suspension parts
- Wheel alignment
- VDC CONTROL MODULE & H/U
- VDC CONTROL MODULE & H/U bracket
- Park the vehicle on a level surface, and set the steering wheel to the neutral position.
- Perform the VDC sensor 0 point setting mode.
- Connect the Subaru Select Monitor.NOTE: For detailed operation procedures, refer to "Application Help".
- Turn the ignition switch to ON.
- On «Start» display, select «Diagnosis».
- On «Vehicle selection» display, input the target vehicle information and select «Confirmed».
- On «Main Menu» display, select «Each System».
- On «Select System» display, select «Brake Control System» and select «Enter».
- On «Select Function» display, select «Data Monitor».
- From the data monitor item list, select «Steering Angle Sensor», «Longitudinal G Sensor» and «Lateral G sensor Output».
- Check that the steering angle sensor output value is within the range of following values.
- Model without Eye-Sight: -10 - 10 deg
- Model with Eye-Sight: -2 - 2 deg
NOTE: If the output value is different from the standard value, check the steering wheel. - Check that output values for the longitudinal G sensor and lateral G sensor are -2 - 2 m/s2
.NOTE: If the output value is not at the standard value, check the installing condition of the VDC CONTROL MODULE & H/U and VDC CONTROL MODULE & H/U bracket.
- On «Select Function» display, select «Work Support».
- From the work support item list, select «VSC (VDC) Centering Mode», and perform the setting according to the procedure displayed on the Subaru Select Monitor screen.
- Connect the Subaru Select Monitor.
- Drive the vehicle for 10 minutes, and check that there is no system malfunction or the warning light illumination while driving.
- Make sure that the DTC is not stored.