| Active test items | Contents | Execution condition | ||
|---|---|---|---|---|
| Fuel Pump Relay | ON/OFF of the fuel pump can be set. | Ignition switch is ON (engine OFF) | ||
| CPC Solenoid Valve | ON/OFF of the purge control solenoid valve can be set. | |||
| Radiator Fan Relay | ON/OFF of the radiator fan relay can be set. | |||
| A/C Compressor Relay | ON/OFF of the A/C relay can be set. | |||
| Turbocharger Wastegate Solenoid | Wastegate control solenoid valve can be set between 0% ←→ 99.6%. | |||
| CPC Solenoid 2 | ON/OFF of the purge control solenoid valve 2 can be set. | |||
| ELCM switching valve | ON/OFF of the leak check valve assembly switching valve can be set. | |||
| ELCM pump | ON/OFF of the leak check valve assembly vacuum pump can be set. | |||
| Fuel Pump Control (OFF Drive) | Fuel pump can be set to OFF. | At idling | ||
| Fixed Idle Ignition Timing | Idle ignition timing can be set and fixed to 10°. | |||
| Idle Speed Control | Idle speed can be set to 500 - 2000 rpm. | |||
| Injection Stop Mode (Injector 1) Injection Stop Mode (Injector 2) Injection Stop Mode (Injector 3) Injection Stop Mode (Injector 4) |
Injector of each cylinder can be set to stop the fuel injection. | |||
| Injection Quantity Control | The amount of fuel injection can be set to -13 - 20%. | |||
| EGR Valve Control (Step) | EGR control valve can be set to 0 - 255 STEP. | |||
| High Pressure Fuel Inspection | High pressure fuel pipe inspection can be executed. | |||
| Alternator control | Alternator control mode can be set to one of the followings: Low mode Middle mode High mode ExHigh mode (1) |
|||
| Compression monitor | Compression can be measured. |
|
||
|
||||