LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 2020 >> Ascent Base >> Repair and Diagnosis >> Electrical >> Charging Systems >> Engine Starting System & Charging System >> General Description >> Specification
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Engine Starting System & Charging System: General Description: Specification

Item Specifications
Starter Type Reduction type
Model M000TC0471
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 1.2 kW
Direction of rotation Counterclockwise (when observed from pinion)
Number of pinion teeth 9
Armature commutator runout Standard 0.05 mm (0.0020 in)
Limit 0.10 mm (0.0039 in)
Armature depth of segment mold Standard 0.50 mm (0.020 in)
Brush length Standard 12.45 mm (0.490 in)
Limit 5.0 mm (0.197 in)
Brush spring force Standard 12.3 - 16.7 N (1.25 - 1.70 kgf, 2.77 - 3.75 lbf)
Limit 3.6 N (0.37 kgf, 0.81 lbf)
No-load characteristics Voltage 11 V
Current 90 A or less
Generator Type Rotating-field three-phase type, voltage regulator built-in type, each with load response control system
Model A2TV0281ZC
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 190 A
Polarity on ground side Negative
Direction of rotation Clockwise (when observed from pulley side)
Stator connection 3-phase Δ type
Output current 1, 500 r/min - 52 A or more 2, 500 r/min - 155 A or more
5, 000 r/min - 190 A or more
Regulated voltage 14.0 - 14.6 V [20°C (68°F)]
Rotor slip ring outer diameter Standard 22.7 mm (0.894 in)
Limit 22.1 mm (0.870 in)
Battery Type 75D23L
Nominal capacity 5 HR: 52 Ah [25°C (77°F)]
Nominal voltage 12 V
CCA 530 A
BCI group number(1) 35
(1) Use the information about the battery size as a reference. This information shall not be guaranteed by SUBARU CORPORATION.