Unit Inspection
- Fuel pressure sensor check
- Output voltage check
- Measure the voltage between the terminals.
VOLTAGE SPECIFICATIONInspection terminals Inspection conditions Standard value 3(VOUT1) - 2(GND) Apply 5 V voltage between the terminals 4 (VCC) and 2 (GND). Approx. 0.5 V CAUTION:- Wrong connection of the inspection terminals may damage the fuel pressure sensor. Pay special attention to the connection work.
- Do not apply voltage of 6 V or higher between the terminals 4 (VCC) and 2 (GND).
NOTE: If a stabilized power source is not available, use nickel hydride batteries (1.2 V x 4) etc.
- Output voltage check