Primary Speed Sensor: Installation
CAUTION:
If water or oil contacts the connector terminal of primary speed sensor, replace it with a new part.
- Install the primary speed sensor using a new O-ring, and connect the connector.NOTE: Apply CVTF to the O-rings.
Tightening torque:
5 N.m (0.5 kgf-m, 3.7 ft-lb)
- Install the intercooler. Ref. to INTAKE (INDUCTION) (H4DOTC)>Intercooler>INSTALLATION .
- Connect the ground terminal to battery sensor. Ref. to REPAIR CONTENTS>NOTE>BATTERY .