Releasing Of Fuel Pressure
WARNING:
Place "NO OPEN FLAMES" signs near the working area.
CAUTION:
Be careful not to spill fuel.
- Remove the fuse of fuel pump from main fuse box.
- Navigate to the service mode (for exhaust gas measurement). Ref. to P-HEV HYBRID POWERTRAIN CONTROL (DIAGNOSTICS)>WORK SUPPORT>OPERATION>SERVICE MODE .
- Start the engine and run it until it stalls.
- After the engine stalls, crank it for five more seconds.
- Turn the ignition switch to OFF.
- Install the fuse of fuel pump to the main fuse box.