| Item | Connector No. | Terminal No. | Input/Output signal |
|---|---|---|---|
| Measured value and measuring conditions | |||
| Battery power supply | B280 | 1 | 9 - 16 V |
| B287 | 4 | ||
| Hybrid vehicle control ECU assembly ("P" range) | B281 | 17 | Pulse signal (CAN communication) |
| B281 | 19 | ||
| Stop light switch | B281 | 16 | 9 - 16 V when stop light switch is ON 1 V when stop light switch is OFF |
| "P" range switch | i171 | 40 | Less than 1 V when select lever is in "P" range |
| 9 - 16 V when select lever is in other positions than "P" range | |||
| Solenoid unit output | i84 | 3 | 9 - 16 V when shift lock is released. Less than 1 V when shift lock is operating. |
| Ground | i84 | 4 | Less than 1 V |
| B287 | 1 |