Auto Start Stop OFF Switch: Inspection
- Check that there is no deformation, cracks or other damages.
- Check the resistance between terminals shown in the following table.
Terminal No. Inspection conditions Standard 6 - 8 Switch ON Less than 1 Ω Switch OFF 1 MΩ or more - Apply battery voltage between the terminals shown in the table below to check lighting condition of illumination inside the switch.CAUTION: When applying battery voltage, do not mix up the positive (+) side and the negative (-) side.
Incorrect polarity connection may cause LED damage inside the switch.Terminal No. Inspection conditions Condition 1 (+) - 4 (-) Apply battery voltage. Light ON