LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 2021 >> Forester Base >> Repair and Diagnosis >> Electrical >> Charging Systems >> Engine Starting System & Charging System >> General Description >> Specification
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Engine Starting System & Charging System: General Description: Specification

Item Specifications
Starter Type Reduction type
Model M000TF1171
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 1.4 kW
Direction of rotation Counterclockwise (when observed from pinion)
Number of pinion teeth 12
No-load characteristics Voltage 11 V
Current 90 A or less
Generator Type Rotating-field three-phase type, voltage regulator built-in type, each with load response control system
Model A5TV0881 or A5TV1281
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 150 A
Polarity on ground side Negative
Direction of rotation Clockwise (when observed from pulley side)
Stator connection 3-phase A type
Output current 1, 500 r/min - 44 A or more [13.5 V]
2, 500 r/min - 121 A or more [13.5 V]
5, 000 r/min - 148 A or more [13.5 V]
Regulated voltage 14.0 - 14.6 V [20°C (68°F)]
Rotor slip ring outer diameter Standard 22.7 mm (0.894 in)
Limit 22.1 mm (0.870 in)
Battery Type Q-85
Nominal capacity 5 HR: 51 Ah, 20HR: 62 Ah [25°C (77°F)]
Nominal voltage 12 V
CCA 620 A
BCI group number(1) N/A
(1) Use the information about the battery size as a reference. This information shall not be guaranteed by SUBARU CORPORATION.