Inhibitor Switch: Adjustment
- Release the shift lock using a screwdriver, etc. and shift the select lever to the "N" range.
- Loosen the bolts holding the inhibitor switch.
- Insert the ST into the holes of the shifter arm and inhibitor switch.NOTE: Set the parts so that the center points of the holes are aligned.
Preparation tool:
ST: STOPPER PIN (499267300)
- Tighten the bolts holding the inhibitor switch.
Tightening torque:
5 N.m (0.5 kgf-m, 3.7 ft-lb)