Inhibitor Switch: Installation
- Temporarily connect the inhibitor switch, and connect the connector.
- Install the shifter arm and fix with a new spring pin.
- Connect the select cable to the transmission main body.CAUTION: Do not apply excessive load while holding the part (a).NOTE: Set the washer before installing the snap pin.
Tightening torque:
25 N.m (2.5 kgf-m, 18.4 ft-lb)
- Adjust the inhibitor switch. Ref. to CONTINUOUSLY VARIABLE TRANSMISSION (TR580)>INHIBITOR SWITCH>ADJUSTMENT .
- Shift the select lever to "P range".
- Connect the ground terminal to battery sensor. Ref. to GROUND TERMINAL REMOVAL OR INSTALLATION .