Secondary Pressure Sensor: Installation
CAUTION:
If water or oil contacts the connector terminal of secondary pressure sensor, replace it with a new part.
- Install the secondary pressure sensor using a new O-ring, and connect the connector.NOTE: Apply CVTF to the O-rings.
Tightening torque:
39 N.m (4.0 kgf-m, 28.8 ft-lb)
- Install the front exhaust pipe, Ref. to EXHAUST (H4DO)>FRONT EXHAUST PIPE>INSTALLATION .
- Connect the ground terminal to battery sensor. Ref. to GROUND TERMINAL REMOVAL OR INSTALLATION .
- Check the CVTF level. Ref. to CONTINUOUSLY VARIABLE TRANSMISSION (TR580)>CVTF>INSPECTION .