Time Series Freeze Frame Data
ECM obtains freeze frame data every 0.5 seconds. When DTC is detected, freeze frame data of [Detect], [1 before], [History2] and [History3] is saved. (Time series freeze frame data)
NOTE:
- You can utilize the time series freeze frame data for diagnosis by checking the status of data changes three times earlier than the DTC was detected.
- For detailed operation procedures, refer to "COMMON (DIAGNOSTICS)". Ref. to COMMON (DIAGNOSTICS)>FREEZE FRAME DATA>OPERATION .
| (A) | [Detect] |
| (B) | [1 before] |
| (C) | [History2] |
| (D) | [History3] |
| (E) | Current |
| (F) | Past |
| (G) | 0.5 sec. |