Variant Work: Notes
Perform when replacing with a new combination meter assembly.
- When the combination meter before replacement can communicate with Subaru Select Monitor ([Read Control module setting information] is workable): Perform the operation procedure A.
- When the combination meter before replacement cannot communicate with Subaru Select Monitor ([Read Control module setting information] is not workable): Perform the operation procedure B.
CAUTION:
When incorrect information is written by [Reading and Writing of the ECU Configuration Information and Odometer Value], [Write ECU setting save data] and [Write ECU setting 12 columns of models], a new combination meter cannot be used because correct information is not displayed. Obtain another new combination meter and write information again.
| Item | Contents | |||||
|---|---|---|---|---|---|---|
| [Read Control module setting information] | Read the setting information from the combination meter before replacement, and save it to the Subaru Select Monitor.(1) |
|||||
| [Write Control module setting information] | [Write ECU setting save data] | Write the setting information saved by [Read Control module setting information] to the new combination meter.(2) | ||||
| [Write ECU setting 12 columns of models] | Using applied models and option codes, write the setting information to the new combination meter.(2) | |||||
| [Reading and Writing of the ECU Configuration Information and Odometer Value] | Read the setting information and odometer value from the combination meter before replacement, and write them to the new combination meter. | |||||
|
||||||