Primary Speed Sensor: Installation
CAUTION:
If water or oil contacts the connector terminal of primary speed sensor, replace it with a new part.
- Install the primary speed sensor using a new O-ring, and connect the connector.NOTE: Apply CVTF to the O-rings.
Tightening torque:
7 N.m (0.7kgf-m, 5.2ft-lb)
- Install the intercooler. Ref. to INTAKE (INDUCTION) (H4DOTC)>INTERCOOLER>INSTALLATION .
- Connect the ground terminal to battery sensor. Ref. to REPAIR CONTENTS>NOTE>BATTERY .