Active Test: List
| Item | Contents | Execution condition | ||
|---|---|---|---|---|
| Electric oil pump control (Relay ON/OFF drive) | ON/OFF of the electric oil pump relay (Auto Start Stop) can be set. |
|
||
| Electric oil pump control (Pump ON/OFF drive) |
|
|
||
| Sub power supply control (ON/OFF Dr.) | DC/DC converter can be set to ON (2 seconds). | "Common execution condition" established | ||
| Engine stop control (1) | Auto Start Stop can be performed without driving the vehicle. | Auto Start Stop condition is established Ref. to AUTO START STOP (DIAGNOSTICS)>DATA MONITOR . | ||
|
NOTE:
|
||||
Common execution condition
- CAN communication for engine is normal
- Following conditions are established
| Item | Value |
|---|---|
| Ignition Switch (Auto Start Stop) | ON |
| System Voltage (Auto Start Stop) | 12.1 V or more |
| Engine Speed (Auto Start Stop) | 0 rpm |
| Vehicle Speed | 0 km/h (0 MPH) |
| Idling Stop Control | Other than during control |