Terminal No. Contents Measuring condition Standard Note
Door mirror (driver's seat) Door mirror (passenger's seat)
(Df21) or (Df23) No. 1 ←→ Chassis ground Memory sensor power supply Memory sensor power supply Always 5.0 V -
(Df21) or (Df23) No. 2 ←→ Chassis ground Memory sensor input (horizontal) Memory sensor input (horizontal) Always 0 - 5.0 V
  • Outer mirror control module LH Changes when the left side mirror surface is operated in the left/right direction Right direction (inward): 0 V - Left direction (outward): 5.0 V
  • Outer mirror control module RH Changes when the right side mirror surface is operated in the left/right direction Left direction (inward): 0 V - Right direction (outward): 5.0 V
(Df21) or (Df23) No. 3 ←→ Chassis ground Memory sensor input (vertical) Memory sensor input (vertical) Always 0 - 5.0 V Changes when the mirror surface is operated in the up/down direction Up direction: 0 V - Down direction: 5.0 V
(Df21) or (Df23) No. 4 ←→ Chassis ground SET SW input - Switch ON 1.6 V or less -
Switch OFF 10 KΩ or more -
(Df21) or (Df23) No. 5 ←→ Chassis ground Memory 1 SW input - Switch ON 1.6 V or less -
Switch OFF 10 KΩ or more -
(Df21) or (Df23) No. 6 ←→ Chassis ground Memory 2 SW input - Switch ON 1.6 V or less -
Switch OFF 10 KΩ or more -
(Df21) or (Df23) No. 7 ←→ Chassis ground GND GND Always 1 Ω or less -
(Df21) or (Df23) No. 8 ←→ Chassis ground Remote control mirror SW MCL input (L side) - When the mirror surface is operated (up) 3.7 V or more Common to both the right and left mirror operation
When the mirror surface is operated (down) 1.6 V or less Common to both the right and left mirror operation
When the mirror surface is operated (right) 3.7 V or more Common to both the right and left mirror operation
When the mirror surface is operated (left) 1.6 V or less Common to both the right and left mirror operation
(Df21) or (Df23) No. 9 ←→ Chassis ground Remote control mirror SW MAR input (R side) - When the mirror surface is operated (up) 10 KΩ or more Only when the right mirror is operated
When the mirror surface is operated (down) 10 KΩ or more Only when the right mirror is operated
When the mirror surface is operated (right) 1.6 V or less Only when the right mirror is operated
When the mirror surface is operated 3.7 V or more (left) Only when the right mirror is operated
(Df21) or (Df23) No. 10 ←→ Chassis ground Remote control mirror SW MBR input (R side) - When the mirror surface is operated (up) 1.6 V or less Only when the right mirror is operated
When the mirror surface is operated (down) 3.7 V or more Only when the right mirror is operated
When the mirror surface is operated (right) 10 KΩ or more Only when the right mirror is operated
When the mirror surface is operated (left) 10 KΩ or more Only when the right mirror is operated
(Df21) or (Df23) No. 11 ←→ Chassis ground Remote control mirror SW MAL input (L side) - When the mirror surface is operated (up) 10 KΩ or more Only when the left mirror is operated
When the mirror surface is operated (down) 10 KΩ or more Only when the left mirror is operated
When the mirror surface is operated (right) 1.6 V or less Only when the left mirror is operated
When the mirror surface is operated (left) 3.7 V or more Only when the left mirror is operated
(Df21) or (Df23) No. 12 ←→ Chassis ground Remote control mirror SW MBL input (L side) - When the mirror surface is operated (up) 1.6 V or less Only when the left mirror is operated
When the mirror surface is operated (down) 3.7 V or more Only when the left mirror is operated
When the mirror surface is operated (right) 10 KΩ or more Only when the left mirror is operated
When the mirror surface is operated (left) 10 KΩ or more Only when the left mirror is operated
(Df21) or (Df23) No. 13 ←→ Chassis ground Memory sensor GND Memory sensor GND Always 1 Ω or less -
(Df21) or (Df23) No. 14 ←→ Chassis ground ECM power supply ECM power supply Always 9.0 - 16 V -
(Df22) or (Df24) No. 1 ←→ Chassis ground Electric retraction SW input (OPR) - During the extension operation by the electric retraction system 3.3 V or more -
During the retracting operation by the electric retraction system 10 KΩ or more -
(Df22) or (Df24) No. 2 ←→ Chassis ground Remote control mirror SW power supply - When the electric retraction system and mirror surface are operated 9.0 - 16 V -
(Df22) or (Df24) No. 3 CAN communication Hi CAN communication Hi - Cannot be measured -
(Df22) or (Df24) No. 4 CAN communication Low CAN communication Low - Cannot be measured -
(Df22) or (Df24) No. 5 ←→ Chassis ground Output for courtesy light Output for courtesy light When door is open (+B voltage) -0.8 V or more -
(Df22) or (Df24) No. 6 ←→ Chassis ground Mirror surface motor output (vertical) Mirror surface motor output (vertical) When the mirror surface is operated (up) 1.0 V or less -
When the mirror surface is operated (down) (+B voltage) -0.6 V or more -
When the mirror surface is operated (right) 10 KΩ or more -
When the mirror surface is operated (left) 10 KΩ or more -
(Df22) or (Df24) No. 7 ←→ Chassis ground Mirror surface motor output (horizontal) Mirror surface motor output (horizontal) When the mirror surface is operated (up) 10 KΩ or more -
When the mirror surface is operated (down) 10 KΩ or more -
When the mirror surface is operated (right) 1.0 V or less -
When the mirror surface is operated (left) (+B voltage) -0.6 V or more -
(Df22) or (Df24) No. 8 ←→ Chassis ground Mirror surface motor output (common) Mirror surface motor output (common) When the mirror surface is operated (up) (+B voltage) -0.6 V or more -
When the mirror surface is operated (down) 1.0 V or less -
When the mirror surface is operated (right) (+B voltage) -0.6 V or more -
When the mirror surface is operated (left) 1.0 V or less -
(Df22) or (Df24) No. 9 ←→ Chassis ground Remote control mirror SW GND - Always 10 KΩ or more -
(Df22) or (Df24) No. 10 ←→ Chassis ground Electric retraction SW input (CLR) - During the extension operation by the electric retraction system 10 KΩ or more -
During the retracting operation by the electric retraction system 3.3 V or more -
(Df22) or (Df24) No. 11 ←→ Chassis ground IGN SW input IGN SW input IG ON 9.0 - 16 V -
(Df22) or (Df24) No. 12 ←→ Chassis ground ACC SW input ACC SW input ACC ON 9.0 - 16 V -
(Df22) or (Df24) No. 13 ←→ Chassis ground Electric retraction SW illumination output - Night illumination ON (+B voltage) -0.3 V or more -
(Df22) or (Df24) No. 14 ←→ Chassis ground Heater output Heater output Defogger ON (+B voltage) -0.8 V or more -
(Df22) or (Df24) No. 15 ←→ Chassis ground Electric retraction motor output (-) Electric retraction motor output (-) During the extension operation by the electric retraction system (+B voltage) -1.1 V or more -
During the retracting operation by the electric retraction system 0.9 V or less -
(Df22) or (Df24) No. 16 ←→ Chassis ground Electric retraction motor output (+) Electric retraction motor output (+) During the extension operation by the electric retraction system 0.9 V or less -
During the retracting operation by the electric retraction system (+B voltage) -1.1 V or more -