Check Valve
Remove check valve. Connect vacuum pump to Brown side of check valve. Apply vacuum. Needle of gauge should remain at or near zero. Reverse check valve. Apply vacuum to Black side of check valve. Needle of gauge should rise considerably; however, it should drop back to zero position as soon as pump action is ceased.