Cooling System Specifications
COOLING SYSTEM SPECIFICATIONS
| Application | Specification | ||||||
|---|---|---|---|---|---|---|---|
| Cooling System Capacity (1) | |||||||
| Samurai | 5.0 Qts. (4.8L) | ||||||
| Sidekick | |||||||
| A/T | 5.5 Qts. (5.2L) | ||||||
| M/T | 5.6 Qts. (5.3L) | ||||||
| Swift | 4.2 Qts. (4.0L) | ||||||
| Pressure Cap | |||||||
| Samurai & Sidekick | 13 psi (.91 kg/cm2 ) | ||||||
| Swift | 12.8 psi (.88 kg/cm2 ) | ||||||
| Thermostat | |||||||
| Samurai & Swift (2) | |||||||
| "A" Thermostat | 190°F (88°C) | ||||||
| "B" Thermostat | 197°F (92°C) | ||||||
| Sidekick | 176-183°F (80-84°C) | ||||||
|
|||||||