ECM Ground Circuits
Disconnect ECM connector. Check continuity between ground and indicated ECM connector terminal. See ECM POWER & GROUND CIRCUITS table. If continuity does not exist, repair appropriate wire between ECM connector and ground.
ECM POWER & GROUND CIRCUITS
| Application | ECM Connector Terminal No. | |
|---|---|---|
| Power Circuits | ||
| DOHC | A1, A2 & A16 | |
| SOHC | B1 & B7 | |
| Ground Circuits | ||
| DOHC | A13, A14 & B16 | |
| SOHC | A7 & B6 | |