DTC 82 - Calibration Malfunction: Notes
EBCM checks for a malfunction by comparing the calibration value to a known value stored in the EEPROM. DTC is also used as a security measure to prevent improper use of calibrations or changes of these calibrations that may alter the designed function of ABS.
NOTE:
Test numbers refer to test numbers on diagnostic chart.
- Checks to see if the malfunction is present during diagnosis. If present, the EBCM is not functioning correctly and must be replaced.