LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2000 >> Swift GA, Automatic >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generators & Regulators >> On-Vehicle Testing >> Generator Output >> Swift
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Generator Output: Swift

  1. Check generator wiring harness electrical connections at generator. Check drive belt tension. See BELT TENSION  under ADJUSTMENTS. Ensure battery is fully charged.
  2. Connect voltmeter between ground and generator "B" (battery) terminal. Connect ammeter positive lead to generator "B" (battery) terminal. Connect ammeter negative lead to positive battery terminal on the battery. See Figure .
  3. To check generator no-load output, ensure all accessories are off. Start and idle engine. Increase engine speed to 2000 RPM and note output voltage and output amperage. Output voltage and output amperage should be within specification. See GENERATOR OUTPUT SPECIFICATIONS  table.
    NOTE: Output voltage may vary slightly depending on temperature of IC voltage regulator case.
  4. If output voltage and output amperage are within specification, go to next step. If output voltage is less than specified, go to step  6 . If output voltage exceeds specification, check ground on brushes. If ground on brushes is okay, replace IC voltage regulator. See OVERHAUL  .
  5. To check generator high-load output, allow engine to idle. Increase engine speed to 2000 RPM. Turn on headlights and heater motor. Note output amperage. Output amperage should be at least 20 amps. If output amperage is less than 20 amps, go to next step.
  6. Repair or replace generator as necessary. If repairing generator, see BENCH TESTING  .
GENERATOR OUTPUT SPECIFICATIONS

Application Specification
Esteem & Swift
Output Amperage
At No-Load 10 Amps Maximum
At High-Load 20 Amps Minimum
Output Voltage (1) 14.4-15.0 Volts
Grand Vitara & Vitara (85-Amp Generator)
Output Amperage
At No-Load 10 Amps Maximum
At High-Load 30 Amps Minimum
Output Voltage (1) 14.1-15.2 Volts
Vitara (60- & 70-Amp Generator)
Output Amperage
At No-Load 10 Amps Maximum
At High-Load (2)
Output Voltage (1) 14.4-15.0 Volts
(1) Output voltage specification listed is at 68°F (20°C). Output voltage may vary slightly depending on temperature of IC voltage regulator case.
(2) On 60-amp generator, minimum output specification is 42 amps. On 70-amp generator, minimum output specification is 49 amps.