Generator Specifications
GENERATOR SPECIFICATIONS
| Application | Specification | ||||
|---|---|---|---|---|---|
| Brush Length | |||||
| 60A/70A | |||||
| Standard | .63" (16 mm) | ||||
| Limit (Minimum) | .08" (2 mm) | ||||
| 80A | |||||
| Standard | .413" (10.5 mm) | ||||
| Limit (Minimum) | .177" (4.5 mm) | ||||
| 105A | |||||
| Standard | .413" (10.5 mm) | ||||
| Limit (Minimum) | .059" (1.5 mm) | ||||
| Condenser (60A/70A) | .5uF | ||||
| Rotor Resistance | |||||
| 60A/70A | 2.5 - 2.9 ohms | ||||
| 80A | 2.9 ohms | ||||
| 105A (1) | 1.6 - 2.0 ohms | ||||
| Rotor Slip Ring | |||||
| Standard | .559 - .567" (14.2 - 14.4 mm) | ||||
| Limit (Minimum) | .504" (12.8 mm) | ||||
| Rotation | Clockwise viewed from pulley side | ||||
| Setting Voltage | |||||
| 60A/70A | 14.4 - 15.0V | ||||
| 80/105A | 14.2 - 14.8V | ||||
| Output (Maximum) | |||||
| 60A | 60A | ||||
| 70A | 70A | ||||
| 80A | 80A | ||||
| 105A | 105A | ||||
|
|||||