Throttle Position Sensor
NOTE:
Perform all voltage and resistance tests using a Digital Volt-Ohm Meter (DVOM) with a minimum 10-megohm input impedance.
THROTTLE POSITION SENSOR RESISTANCE
| Application |
Ohms |
| Aerio |
| Between Terminals No. 1 & 2 |
100-6500 |
| Between Terminals No. 1 & 3 |
4000-6000 |
| Grand Vitara & XL-7 |
| Between Terminals No. 1 & 3 |
4000-6000 |
| Between Terminals No. 2 & 3 |
0-4600 |
| Vitara |
| Between Terminals No. 1 & 2 |
20-6000 |
| Between Terminals No. 1 & 3 |
4000-6000 |
| XL-7 |
| Between Terminals No. 1 & 2 |
20-6000 |
| Between Terminals No. 1 & 3 |
4000-6000 |
Courtesy of SUZUKI OF AMERICA CORP. THROTTLE POSITION SENSOR VOLTAGE
| Application |
Volts |
| Aerio |
| Throttle Fully Close |
.35-.65 |
| Throttle Fully Open |
3.5-4.5 |
| Grand Vitara |
| Throttle Fully Close |
.35-.65 |
| Throttle Fully Open |
3.5-4.5 |
| Vitara |
| Throttle Fully Close |
.50-1.2 |
| Throttle Fully Open |
3.4-4.7 |
| XL-7 |
| Throttle Fully Close |
.49-.91 |
| Throttle Fully Open |
3.76-4.36 |