Enable Conditions
Ignition Voltage > 10 V
AND Ignition Voltage < 16 V
AND Barometric pressure > 72 kPa
AND Engine off time > 720 min.
OR (Startup IAT - Startup ECT < 12 °C
AND Startup ECT - Startup IAT) < 12 °C
AND Startup ECT > 0 °C
AND Startup ECT < 40 °C
AND Startup IAT > 0 °C
AND Startup IAT < 40 °C
AND Startup IAT - IAT < 3 °C
AND Engine Run Time > 1 s
AND Purge enable time < .
AND Cold test timer < 360 s
AND Fuel level > 0.06%
AND Fuel level < 0.93%
AND Restricted path test time < 220 s