Enable Conditions
Determination of Steady Conditions
IF Engine Running = RUN
Delta MAP =< 10 kPa
AND Delay Timer >= 5 s
THEN Set Delta MAP Condition Not Exceeded Flag to TRUE = TRUE
OR
Delta RPM =< 50 RPM
AND Delay Timer >= 5 s
THEN Set Delta RPM Condition Not Exceeded Flag to TRUE = TRUE
OR
Throttle Position =< 1.9989%
AND Delay Timer >= 5 s
THEN Set TPS Condition Not Exceeded Flag to TRUE = TRUE
OR
Vehicle Speed >= 1 kph
AND For Delay Timer of >= 5 s
THEN Set V. Speed Condition Not Exceeded Flag to TRUE = TRUE
Determination of Noisy Signal Enable Condition
IF Engine Running = RUN
AND Intake Air temperature >= -10
AND Fuel Level Active Fault Present = FALSE
AND Noisy Signal Disabling Faults Present? = FALSE
AND Delta MAP Condition Exceeded = FALSE
AND Delta RPM Condition Exceeded = FALSE
AND TPS Condition Exceeded = FALSE
AND Vehicle Speed Condition Exceeded = FALSE
THEN Set Enable Criteria Met Conditions are Satisfied = TRUE