Secondary Parameters And Enable Conditions
Limits:
Enable Conditions:
- No EGR error
- 1,376 rpm < RPM < 2,720 rpm
- -256 rpm/s < Moving Mean value of engine speed gradient < 192 rpm/s
- MAP > 150 hPa
- 2.341° TPS < Actual TPS value < Table (Up to 13.122° TPS)
- 10.968 V < Battery voltage < 15.640 V
- Air Temp. at the throttle body >= -15 °C
- Ambient pressure >= 740.04 hPa
- -704 rpm/s < Engine speed gradient < 288 rpm/s
Permanent:
Enable Conditions:
- No EGR error
- 1,376 rpm < RPM < 2,720 rpm
- -256 rpm/s < Moving Mean value of engine speed gradient < 192 rpm/s
- MAP > 150 hPa
- 2.341° TPS < Actual TPS value < Table (Up to 13.122° TPS)
- 10.968 V < Battery voltage < 15.640 V
- Air temperature at the throttle body >= -15 °C
- Ambient pressure >= 740.04 hPa
- -704 rpm/s < Engine speed gradient < 288 rpm/s
Leakage:
Enable Conditions:
- No EGR error
- 1,376 rpm < RPM < 2,720 rpm
- -256 rpm/s < Moving Mean value of engine speed gradient < 192 rpm/s
- MAP > 150 hPa
- 2.341° TPS < Actual TPS value < Table (Up to 13.122° TPS)
- 10.968 V < Battery voltage < 15.640 V
- Air Temp. at the throttle body >= -15 °C
- Ambient pressure >= 740.04 hPa
- -704 rpm/s < Engine speed gradient < 288 rpm/s