Manifold Absolute Pressure Check: Troubleshooting
TROUBLESHOOTING CHART
| Step | Action | Value (s) | Yes | No |
|---|---|---|---|---|
| 1 |
Is the difference in the two parameter readings less than the value specified? |
10 kPa | Go to Step 2 | Go to Step 5 |
| 2 |
Is the difference in parameter readings more than the value specified? |
25 kPa | System OK | Go to Step 3 |
| 3 | Inspect the MAP sensor connector terminals. Is the problem found? |
- | Go to Step 4 | Go to Step 5 |
| 4 | Repair the MAP sensor connector terminals as needed. Is the repair complete? |
- | System OK | - |
| 5 | Replace the MAP sensor. Is the repair complete? |
- | System OK | - |