Input Shaft Speed Sensor Inspection
Reference: INPUT SHAFT SPEED SENSOR REMOVAL AND INSTALLATION
- Disconnect negative cable at battery.
- Disconnect input shaft speed sensor connector (2).
- Check resistance between input shaft speed sensor (1) terminals. If check result is not as specified, replace sensor.
Input shaft speed sensor resistance
Standard: 344 - 516 Ω at 20°C (68°F)