Sensor Circuit Monitor
OPERATION (1 OF 3)
| DTC | P0102, P0103, P0112, P0113, P0117, P0118, P0327, P0328, P2228, P2229 |
| Monitor execution | Continuous |
| Monitoring duration | 5 sec. |
OPERATION (2 OF 3)
| DTC | P2122, P2123, P2127, P2128 |
| Monitor execution | Continuous |
| Monitoring duration | 0.5 sec. |
OPERATION (3 OF 3)
| DTC | P0122, P0123, P0222, P0223 |
| Monitor execution | Continuous |
| Monitoring duration | 0.1 sec. |
ENABLE CONDITIONS
| Parameter | Min. | Max. |
|---|---|---|
| P0102, P0103, P0112, P0113, P0117, P0118, P0327, P0328, P2228, P2229 | ||
| None | ||
| P0122, P0123, P0222, P0223, P2122, P2123, P2127, P2128 | ||
| Battery voltage | 6 V | - |
TYPICAL MALFUNCTION THRESHOLDS
| P0102: | Sensor voltage < 0.15 V |
| P0103: | Sensor voltage >= 4.85 V |
| P0112: | Sensor voltage <= 0.15 V |
| P0113: | Sensor voltage >= 4.85 V |
| P0117: | Sensor voltage < 0.15 V |
| P0118: | Sensor voltage >= 4.85 V |
| P0122: | Sensor voltage <= 0.300 V |
| P0123 | Sensor voltage >= 4.642 V |
| P0222: | Sensor voltage <= 0.740 V |
| P0223: | Sensor voltage >= 4.742 V |
| P0327: | Sensor voltage < 1.23 V |
| P0328: | Sensor voltage >= 3.91 V |
| P2122: | Sensor voltage < 0.45 V |
| P2123: | Sensor voltage >= 4.8 V |
| P2127: | Sensor voltage < 0.23 V |
| P2128: | Sensor voltage >= 2.4 V |
| P2228: | Sensor voltage < 0.602 V |
| P2229: | Sensor voltage >= 4.729 V |